105U-L Transmitter & Receiver I/O Pair

The ELPRO 105U-L and 905U-L products are a small I/O count transmitter and receiver pair delivered pre-configured for ease of installation. Just connect the antennas and apply power for them to be operational.  The L series products may be reconfigured into a wider ELPRO I/O or gateway network as application needs grow. DIN rail mounted and DC (9-30V) powered, the units can also power a loop powered device to 24VDC, 30mA.

Features:

  • Flexible usage: pre-configured matched transmitter/ receiver pair; individual use for transmission/ receiving I/O from other devices.
  • Peer-to-peer communications with exception reporting, self-checking of messages via update time and secure data encryption.
  • Multi-hop repeatability of signals when used with multi-I/O and gateway units.
  • Up to 3000 wireless units per network.

Applications: Flow meter monitoring, Storage tank monitoring, Pipeline cathodic protection, Pump stop-start, Lighting bank control, Power reticulation relay fault notifications, Emergency shower notification, Weather station reporting, Bearing condition monitoring

Transmitter Unit Specific Features: Input-only I/O: 2 DI/PI (digital inputs can be pulse inputs), 1 AI, 1 TI (thermocouple mV input). Additional internal inputs: set point (analog), power supply voltage, 24VDC, 30mA analog loop supply.

Receiver Unit Specific Features: Output-only I/O: 3 digital relay/ 1 analog outputs. Communications failure indication and configurable output (retained or reset/fail-safe on communications failure). LED indication of radio signal strength.

Resources

Catalog Number: 105U-L/ 905U-L
Applications: Flow meter monitoring, Storage tank monitoring, Pipeline cathodic protection, Pump stop-start, Lighting bank control, Power reticulation relay fault notifications, Emergency shower notification, Weather station reporting, Bearing condition monitoring
Transmitter Unit Specific Features: Input-only I/O: 2 DI/PI (digital inputs can be pulse inputs), 1 AI, 1 TI (thermocouple mV input). Additional internal inputs: set point (analog), power supply voltage, 24VDC, 30mA analog loop supply.
Receiver Unit Specific Features: Output-only I/O: 3 digital relay/ 1 analog outputs. Communications failure indication and configurable output (retained or reset/fail-safe on communications failure). LED indication of radio signal strength.

Features:

  • 869.525MHz/500mW or 869.875MHz/5mW frequency options.
  • Flexible usage: pre-configured matched transmitter/receiver pair or complex networks via ELPRO
  • I/O and/or Gateway products.
  • Peer-to-peer communications with exception reporting, self-checking of messages via CRC, update time and secure data encryption.
  • Multi-hop repeatability via ELPRO multi-I/O & Gateways products.

Transmitter Features

  • 2 DI/PI (digital inputs can be pulse inputs), 1 AI (4-20mA), 1 TC (thermocouple input -10 100mV).
  • 1 AI 24Vdc, 30mA analog loop supply capable.
  • Additional internal inputs: set point (analog), power supply voltage.

Receiver Features

  • 3 DO (relay outputs), 1 AO (0-20mA/4-20mA).
  • Communications failure indication via configurable output.
  • Receive radio signal strength indication using LED